# Safety Certs UK > Free UK safety certificate and checklist forms that run entirely in the browser: landlord gas safety record (CP12 / LGSR), gas warning notice and gas service / commissioning record with gas rate, pipe sizing and ventilation calculators; legionella risk assessment, HMO fire risk assessment and PEEP templates; EIC, EICR and Minor Works electrical certificates with BS 7671 calculators (max Zs, Zs, R1+R2, voltage drop, cable size), PAT testing certificate generator, fire risk assessment template, fire door inspection / survey checklist, fire safety log book and fire alarm log book. Output is a PDF; nothing typed is uploaded; no account. Facts: - Everything runs client-side. Form data never leaves the device; a draft is kept in the browser's localStorage. The only network calls after page load are anonymous usage beacons (event name and tool id) and, only if the visitor opts in, a waitlist email. - Output: a filled PDF (generated in the browser with pdf-lib) and a blank fillable PDF template (AcroForm fields) for each form; page numbers and a disclaimer on every page; optional drawn or image signature. - PAT certificate: client/site, tester, instrument and calibration, appliance register (asset ID, description, location, class I/II/III/lead, visual, earth continuity ohms, insulation resistance megohms, polarity, functional, result, retest date, notes). Retest dates are calculated from test date + chosen interval. Failed results print in red. - Fire risk assessment: structured on the five steps of the UK government's fire safety risk assessment guides for the Regulatory Reform (Fire Safety) Order 2005 (England and Wales); hazards, people at risk, 14 measure checks, risk rating, action plan, emergency plan, review. Own wording; not PAS 79. - Fire door checklist: per door reference, location, rating (FD30/FD30S/FD60…), type, 13 visual checks (label, leaf, frame, gaps, threshold, seals, hinges, closer, latch, glazing, ironmongery, signage, not wedged open), overall result, remedial actions. Own wording; not BS 8214. - Log books: weekly fire alarm tests, emergency lighting, extinguishers, drills, training, false alarms, servicing (the fire alarm log book is the alarm subset). - Electrical certificates: Electrical Installation Certificate (single signatory: new installation, addition, alteration), Electrical Installation Condition Report (EICR, with C1/C2/C3/FI coded observations, extent and limitations, overall assessment) and Minor Electrical Installation Works certificate. Each has supply characteristics and earthing, particulars at the origin, a schedule of inspections, a circuit schedule and test results (R1+R2, ring r1/rn/r2, insulation resistance, polarity, Zs, RCD time, AFDD). Own layout and wording, based on the BS 7671 Appendix 6 model form requirements; not the IET model forms. - BS 7671 calculators (formulas shown on each page): maximum Zs = 0.95 × 230 V ÷ Ia with Ia = 5/10/20 × In for type B/C/D MCBs and RCBOs (e.g. B32 1.37 Ω, B16 2.73 Ω, B6 7.28 Ω; 80 % of the maximum for comparing with a test reading); RCD fault protection Zs ≤ 50 V ÷ IΔn; Zs = Ze + (R1 + R2) and fault current = 230 ÷ Zs; R1 + R2 from copper resistance per metre at 20 °C (BS EN 60228: 2.5 mm² 7.41, 1.5 mm² 12.1 mΩ/m; × 1.20 at 70 °C; ring = (r1 + r2) ÷ 4); voltage drop mV/A/m = 2 × r × 1.20 (three-phase × √3/2) against 3 % lighting / 5 % other; cable sizing It ≥ In ÷ (Ca × Cg × Ci × Cc). - Gas records (for Gas Safe registered engineers only): landlord gas safety record with appliance/flue rows (location, type, make/model, landlord-owned, inspected, flue type, operating pressure or heat input, safety device, ventilation, flue visual and flue performance tests, CO/CO2 ratio, CO ppm, serviced, safe to use), installation checks (tightness test, ECV, bonding, pipework, CO alarm), defects classified ID / AR / NCS, next check due defaulting to 12 months after the check (regulation 36, Gas Safety (Installation and Use) Regulations 1998); gas warning notice (ID / AR, action taken, labels, RIDDOR, gas emergency 0800 111 999); service / commissioning record with pressures, gas rate, CO/CO2 at high and low fire. Own layout; not the Gas Safe Register or CORGI forms; not affiliated with Gas Safe Register. - Gas calculators: gas rate m³/h = m³ × 3600 ÷ seconds (imperial: ft³ × 3600 ÷ s × 0.0283168); heat input kW gross = m³/h × CV ÷ 3.6 (CV 38.7 MJ/m³ natural gas, 93.1 LPG), net = gross ÷ 1.11 (LPG 1.09); e.g. 0.04 m³ in 120 s = 1.2 m³/h = 12.90 kW gross = 11.62 kW net. Pipe sizing by Pole's formula Q = 0.0071 √(h d⁵ ÷ s L), s = 0.6, copper bores 13.6/20.2/26.2/32.6/39.6 mm, fittings 0.5 m per elbow or tee and 0.3 m per bend, 1 mbar meter-to-appliance limit. Ventilation (as commonly applied from BS 5440-2): open-flued in a room 5 cm² per kW net above 7 kW; compartments open-flued high/low 10/20 cm²/kW to a room or 5/10 to outside, room-sealed 10/10 or 5/5; flueless cooker 100 cm² under 5 m³, 50 cm² for 5–10 m³, none over 10 m³. - Landlord forms: legionella risk assessment (water system, 9 risk factors, outlet temperatures: hot ≥ 50 °C within 1 minute, cold < 20 °C within 2 minutes, stored hot water 60 °C, control measures, review date; follows HSE ACOP L8 / HSG274 Part 2); PEEP (needs, alerting, route, refuge, equipment, named helpers, review); HMO fire risk assessment uses the fire risk assessment form. - Workplace compliance records (2026-11-18): LOLER thorough examination report covering LOLER 1998 Schedule 1 with a next-examination checker (regulation 9(3): 6 months for equipment lifting people and lifting accessories, 12 months for other lifting equipment, or an examination scheme); F-gas equipment record and leak check log covering Article 6 of Regulation (EU) 517/2014 as it applies in GB, with a frequency calculator (t CO2e = kg × GWP ÷ 1000; 5 t → 12 months, 50 t → 6, 500 t → 3, doubled with a leak detection system; hermetically sealed under 10 t exempt; records kept 5 years); COSHH assessment template covering COSHH 2002 regulation 6(2) (LEV examined at least every 14 months, regulation 9); TM44 air-conditioning inspection checker (Energy Performance of Buildings (England and Wales) Regulations 2012: systems over 12 kW combined output, inspected by an accredited energy assessor at intervals not exceeding five years, first inspection within five years of first use) with an air-conditioning unit register; building regulations notifiable-work checker for England (regulation 12(6A): new circuit, consumer unit, special location; Schedule 3 self-certification with certificate and notice within 30 days, regulation 20; Schedule 4 exemptions). Own layouts; not official forms. - CIS calculator (2026-11-18, GOV.UK and HMRC CIS 340): deduction rates 20% registered, 30% unregistered, 0% gross payment status; the deduction is taken from the payment before VAT less what the subcontractor paid directly for materials, plant hire, consumable stores, fuel other than for travel and prefabrication; travel and subsistence stay in; worked both ways (payment to net, net to payment) with VAT at 20% or the domestic reverse charge; example: £600 plus £120 VAT with £200 materials at 20% = £400 × 20% = £80 deducted, £640 paid. Reproduces CIS 340 Appendix D examples. - RAMS template: free risk assessment and method statement PDF (hazards, who is at risk, controls, sequence of works, PPE, emergency arrangements, sign-off, operatives briefed). RAMS is a trade term, not a legal one; the legal duty is the risk assessment (Management of Health and Safety at Work Regulations 1999, regulation 3); method statements are good practice except that HSE says arrangements for demolition, dismantling or structural alteration must be recorded in writing before work begins. Own layout; not an official HSE form. - Disclaimer: the tool records what the user enters; it does not inspect, test or assess. Competence and compliance remain with the user. Not legal advice. - Language: British English. Price: forms, calculators and PDFs are free with no account; saving certificates is a paid business plan (Pro £39/month or Business £79/month, ex VAT, businesses only). Independent; not affiliated with HSE, any fire and rescue service or certification body. ## Forms and guides - [Safety Certs UK](https://safetycertsuk.com/?ref=llms) - [Fire alarm inspection and servicing certificate (BS 5839-1)](https://safetycertsuk.com/fire-alarm-certificate): Free fire alarm inspection and servicing certificate for BS 5839-1: system category, checks, devices tested, defects and next service date. Fill in online, sign and download a PDF. - [Emergency lighting test certificate (BS 5266-1)](https://safetycertsuk.com/emergency-lighting-certificate): Free emergency lighting periodic inspection and test certificate for BS 5266-1: system, duration test, luminaire schedule, defects and next test date. Fill in online and download a signed PDF. - [PAT testing certificate generator](https://safetycertsuk.com/pat-testing-certificate): Make a PAT testing certificate online for free: appliance register with visual, earth continuity, insulation and functional results, retest dates and your signature. Download as PDF; nothing is uploaded. - [PAT testing certificate template](https://safetycertsuk.com/pat-testing-certificate-template): Free PAT testing certificate template download: a blank fillable PDF with an appliance register, or fill it in online and download it completed. CSV for Excel on the record sheet. No sign-up. - [Free PAT testing software that runs in your browser](https://safetycertsuk.com/pat-testing-software): Free online PAT testing software: build an appliance register, record results and print certificates in your browser. No installation, no account, nothing uploaded. - [Fire risk assessment template](https://safetycertsuk.com/fire-risk-assessment-template): Free fire risk assessment template for small premises in England and Wales, built around the five steps: hazards, people at risk, measures, action plan and review. Fill in online, download as PDF. - [Fire door inspection checklist (and what an inspection costs)](https://safetycertsuk.com/fire-door-inspection): Free fire door inspection checklist for your phone (PDF or CSV), plus what UK firms publish for fire door inspection cost per door, what drives the price, and which checks you can do yourself. - [Fire door survey template](https://safetycertsuk.com/fire-door-survey): Free fire door survey template: a door-by-door register with fire rating, door type, 13 condition checks, overall result and remedial actions. Fill in online or print a blank fillable PDF. - [Fire safety log book](https://safetycertsuk.com/fire-safety-log-book): Free fire safety log book: weekly fire alarm tests, emergency lighting, extinguisher checks, fire drills, training, false alarms and servicing. Fill in online or print a blank PDF log book. - [Fire alarm log book](https://safetycertsuk.com/fire-alarm-log-book): Free fire alarm log book for weekly call point tests, false alarms, faults and servicing visits. Fill in online and download as PDF, or print a blank log to keep by the panel. - [Legionella risk assessment for landlords: free template](https://safetycertsuk.com/legionella-risk-assessment-template): Free legionella risk assessment template for landlords: water system, risk factors, hot and cold water temperatures, control measures and review date, following HSE ACOP L8 and HSG274. Fill in online and download a PDF. - [PEEP template: personal emergency evacuation plan](https://safetycertsuk.com/peep-template): Free PEEP template: the person’s needs, how they are alerted, escape route, refuge, equipment, named helpers and review date. Fill in online with the person and download a PDF. - [HMO fire risk assessment template](https://safetycertsuk.com/hmo-fire-risk-assessment): Free HMO fire risk assessment template: hazards, people at risk, alarms, escape routes, fire doors, emergency lighting, risk rating and action plan for houses in multiple occupation. Fill in online and download a PDF. - [LOLER inspection: next examination date and report template](https://safetycertsuk.com/loler-inspection): Work out when your next LOLER thorough examination is due (6 or 12 months, or a scheme) and fill in a thorough examination report covering LOLER Schedule 1. Free PDF in your browser. - [F-gas leak check record and frequency calculator](https://safetycertsuk.com/f-gas-leak-check): F-gas leak check frequency from refrigerant charge and GWP (5, 50, 500 t CO2e), next check date and a free equipment record and leak check log covering Article 6 of the GB F-gas Regulation. - [COSHH assessment template](https://safetycertsuk.com/coshh-assessment-template): Free COSHH assessment template covering regulation 6 of COSHH 2002: substance, SDS hazards, exposure routes, workplace exposure limit, controls, PPE, LEV, health surveillance, actions and review date. PDF in your browser. - [TM44 air-conditioning inspection: due date checker](https://safetycertsuk.com/tm44-inspection): Is a TM44 air-conditioning inspection required (over 12 kW) and when is it due? Free checker from the Energy Performance of Buildings Regulations 2012 plus an air-con register with next inspection date. - [Building regulations compliance certificate: notifiable work checker](https://safetycertsuk.com/building-regulations-compliance-certificate): Check if your work is notifiable under the Building Regulations 2010 in England (new circuit, consumer unit, boiler, windows, roof, extension) and which certificate you should get: compliance or completion certificate. - [CIS calculator: deduction and net payment](https://safetycertsuk.com/cis-calculator): Free CIS deduction calculator. Work out the 20%, 30% or 0% CIS deduction and the net payment from the invoice, or the invoice from the net you want, with materials and VAT handled the way HMRC’s CIS 340 guide does. - [RAMS template: risk assessment and method statement](https://safetycertsuk.com/rams-template): Free RAMS template: fill in hazards, who is at risk, controls, the sequence of works, PPE and sign-off, then download a PDF. Based on HSE guidance and the Management of Health and Safety at Work Regulations 1999. - [Gas certificates and calculators for engineers](https://safetycertsuk.com/gas-certificates): Free gas certificate forms for Gas Safe engineers: landlord gas safety record (CP12), gas warning notice and service / commissioning record, plus gas rate, pipe sizing and ventilation calculators. PDF in your browser. - [CP12 certificate: landlord gas safety record](https://safetycertsuk.com/cp12-certificate): Free CP12 / landlord gas safety record for Gas Safe engineers: appliances and flues, operating pressure or heat input, flue and safety device checks, defects and next check date. Fill in online, sign and download a PDF. - [Gas warning notice](https://safetycertsuk.com/gas-warning-notice): Free gas warning notice for Immediately Dangerous and At Risk situations: appliance, fault, classification, action taken, labels, RIDDOR and the responsible person informed. Fill in, sign and download a PDF. - [Boiler service record and commissioning sheet](https://safetycertsuk.com/boiler-service-record): Free boiler service record and commissioning sheet: appliance details, standing and working pressure, gas rate, CO and CO₂ at high and low fire, checks, parts fitted and next service date. Fill in and download a PDF. - [Gas rate calculator](https://safetycertsuk.com/gas-rate-calculator): Gas rate calculator for metric (m³) and imperial (ft³) meters: work out m³/h and heat input in kW gross and net from a timed meter test, and compare it with the appliance data plate. - [Gas pipe sizing calculator](https://safetycertsuk.com/gas-pipe-sizing-calculator): Gas pipe sizing calculator for natural gas in copper pipe: pressure loss for the load, effective length with elbows, tees and bends, capacity at 1 mbar and the smallest pipe size. Pole’s formula with the working shown. - [Gas ventilation calculator](https://safetycertsuk.com/gas-ventilation-calculator): Gas appliance ventilation calculator: free area for open-flued appliances in a room (5 cm²/kW over 7 kW), high and low compartment vents for open-flued and room-sealed appliances, and flueless cookers by room volume. - [Electrical certificates and BS 7671 calculators](https://safetycertsuk.com/electrical-certificates): Free EIC, EICR and Minor Works certificate templates you fill in online and download as PDF, plus max Zs, Zs, R1 + R2, voltage drop and cable size calculators with the working shown. - [Max Zs values: table and calculator](https://safetycertsuk.com/max-zs-values): Maximum earth fault loop impedance (Zs) for B, C and D type MCBs and RCBOs, worked out from 0.95 × 230 V ÷ Ia, with 80 % test values and RCD limits for TT systems. Free calculator with the working shown. - [Zs calculator (earth fault loop impedance)](https://safetycertsuk.com/zs-calculator): Calculate earth fault loop impedance Zs = Ze + (R1 + R2), the prospective earth fault current and whether the MCB disconnects in time. Free BS 7671 calculator with the working shown. - [R1 + R2 calculator](https://safetycertsuk.com/r1-r2-calculator): Calculate R1 + R2 from cable size and length for radial and ring final circuits, end-to-end r1, rn and r2, or R1 + R2 from a Zs reading. Copper resistance per metre and the working shown. - [Voltage drop calculator](https://safetycertsuk.com/voltage-drop-calculator): Calculate cable voltage drop for single-phase 230 V and three-phase 400 V circuits from cable size, current and length, check it against the 3 % lighting and 5 % other limits, and find the longest run. - [Cable size calculator](https://safetycertsuk.com/cable-size-calculator): Work out the minimum tabulated current rating It for a cable from the device rating and correction factors (Ca, Cg, Ci, Cc), check Ib ≤ In ≤ Iz, then check voltage drop and Zs. - [Electrical Installation Certificate (EIC)](https://safetycertsuk.com/electrical-installation-certificate): Fill in an Electrical Installation Certificate online: supply and earthing details, schedule of inspections, circuit schedule and test results, signature. Download as PDF or a blank fillable EIC form. Nothing is uploaded. - [EICR template (electrical installation condition report)](https://safetycertsuk.com/eicr-template): Free EICR form: extent and limitations, observations with C1, C2, C3 and FI codes, supply and earthing, schedule of inspections, circuit schedule and test results. Fill in online and download a PDF, or a blank fillable EICR. - [Minor Works certificate (minor electrical installation works)](https://safetycertsuk.com/minor-works-certificate): Free Minor Electrical Installation Works Certificate: description of work, circuit details, protective device, test results (R1 + R2, insulation resistance, polarity, Zs, RCD) and signature. Fill in online or download a blank fillable form. - [FireCert alternative for a one-off fire alarm certificate](https://safetycertsuk.com/firecert-alternative): FireCert is a £79 to £129 a month platform for fire and security contractors. See how it compares with a free browser form for a BS 5839-1 service certificate. - [PATLog alternative: PAT certificates without an account](https://safetycertsuk.com/patlog-alternative): PATLog is a free, open source PAT record keeper with QR-linked PDF certificates. Compare it with a free browser PAT certificate that stores nothing online. - [LedgerCert alternative: free certificate forms with no account](https://safetycertsuk.com/ledgercert-alternative): LedgerCert offers 32 certificate types free, with Premium at £8.99 a month. Compare it with free browser-only forms for emergency lighting, fire alarm and PAT. - [UK fire, electrical and gas safety duties at a glance](https://safetycertsuk.com/uk-safety-legal-duties): Table of UK duties for fire risk assessment, alarms, emergency lighting, PAT, EICR and gas safety: the law, who it applies to and whether it sets a fixed interval. - [PAT testing record sheet and asset register](https://safetycertsuk.com/pat-testing-record-sheet): Free PAT testing record sheet and appliance asset register: asset ID, location, class, visual, earth, insulation and polarity results, pass/fail and retest due. Download a PDF or a CSV for Excel. Nothing is uploaded. - [Fire door inspection app (UK)](https://safetycertsuk.com/fire-door-inspection-app): Free fire door inspection app for your phone browser (PDF and CSV, nothing uploaded), plus a dated comparison of FireCert, IgnisTrack and DoorTRACE: price, platform, offline mode and exports. ## For AI agents - [Full reference for AI assistants](https://safetycertsuk.com/llms-full.txt) - [For AI agents](https://safetycertsuk.com/for-ai-agents) ## About - [About](https://safetycertsuk.com/about) - [Contact / delete my data](https://safetycertsuk.com/contact-us) - [Privacy](https://safetycertsuk.com/privacy) - [Terms](https://safetycertsuk.com/terms)