Fire door inspection checklist (and what an inspection costs)

Walk round with your phone, tick off 13 checks for each door, note any remedial work and download a PDF or CSV inspection record for all the doors you checked. Below: published UK prices for hiring an inspector.

Firms that publish prices quote about £10 to £30 a door for a basic visual check, £25 to £65 a door for a structured inspection with a report, and £35 to £80 or more a door for a detailed survey with photos, plus a minimum visit fee on small sites (one firm says £200 to £800). Another quotes a fire door survey from £250 plus VAT. In England, a responsible person of a residential building over 11 metres can do the quarterly checks of communal fire doors themselves; gov.uk says a specialist should not be needed for those checks.

Last reviewed · Fire Safety (England) Regulations 2022, regulation 10 (legislation.gov.uk) and the gov.uk fire doors fact sheet; prices from the firms named in the table

🔒 Filled in and turned into a PDF in your browser. Nothing you type is uploaded unless you press “Save to account”; otherwise a draft stays only on this device.

Building and inspector

Doors

Door

Door details

Checks

Certification label, plug or mark present and legible
Door leaf free from damage, holes or unauthorised alterations
Frame secure and undamaged
Gaps around the leaf even and within tolerance (about 3 mm)
Gap at the threshold acceptable
Intumescent strips and smoke seals present and undamaged
Hinges secure, no missing or loose screws
Self-closer closes the door fully from any angle
Latch engages without slamming
Glazing intact with fire-rated beads and seals
Locks, handles and hold-open devices working
Correct signage (e.g. Fire door keep shut)
Not wedged or propped open; route around it clear

Outcome

Inspector signature

Optional. Draw above or pick a PNG/JPG; it stays on your device.

Free PDFs carry a small “Free version” mark. Pro removes it, saves your certificates, adds your logo and company details and reminds you before renewals.

Important: this tool records the results and findings you enter and formats them as a document. It does not inspect, test or assess anything. Competence and compliance remain with the user. Not legal advice.

How much does a fire door inspection cost in the UK?

These are quoted ranges, not averages of real invoices, and the three sources do not agree: the widest gap is between a £10 visual check and a £150 survey. Treat them as a way to sanity-check a quote, not a price list.

Prices as published on the pages named, read 18 November 2026. Guide prices, usually excluding VAT and repairs; check the firm for a quote.
SourcePer doorPer visit or minimumNotes
Fire Risk Assessment Network, fire-risk-assessment-network.com/blog/fire-door-inspection-survey-cost/Basic visual £10 to £30; structured inspection with report £25 to £65; detailed survey with photos and remedial schedule £35 to £80+Small sites: minimum visit or survey fee, often £200 to £800+Says remedial works are quoted separately; travel and re-inspection inclusion not stated
North West Fire Solutions Ltd, nwfiresolutions.co.uk/?p=3395Not statedFire door survey from £250 + VAT, rising to several thousand pounds at sites with hundreds of doorsPage undated
Trade2Base, trade2base.com/blog/fire-door-costs-uk (published 8 June 2026)£50 to £150 per door for inspection or survey, no fitting work includedNot statedTrade guide rather than an inspection firm; block of flats and HMO work at the lower end per door

What drives the price

  • Number of doors: higher volumes often lower the per-door rate, while small sites hit a minimum visit fee.
  • Depth of report: a visual check, a structured inspection with a report, and a survey with photos, defect grading and a remedial schedule are priced differently.
  • Building type: flats, HMOs, care homes, hotels, schools and healthcare.
  • Access: resident appointments and failed-access records.
  • Door type: double, glazed, riser, plant room or altered doors.
  • Location, travel and short-notice work.
  • Repairs and replacement doorsets are quoted separately and cost far more than the inspection.

Checks you can do yourself and when to hire a specialist

The gov.uk fact sheet on regulation 10 says the responsible person should be able to carry out the routine checks themselves, that it should not be necessary to engage a specialist for them, and that the minimum is an inspection of the doors for obvious damage or issues. It points to glazing, air transfer grilles, gaps around the frame, seals, hinges, the self-closer and visible damage.

The same fact sheet says that where issues are found it might be appropriate to carry out more detailed checks, which could include engaging a specialist. A detailed examination of fire resistance is a matter for the fire risk assessment, not the routine check. This free form covers the routine visual check; it is not a substitute for a survey by a competent person.

Fire Safety (England) Regulations 2022, regulation 10 (legislation.gov.uk/uksi/2022/547/regulation/10/made): buildings with two or more sets of domestic premises above 11 metres.
DoorsDutyFrequency
Communal fire doorsResponsible person must check themAt least every 3 months
Flat entrance doorsResponsible person must use best endeavours to check themAt least every 12 months

Export the inspection as CSV

“Download CSV / Excel” gives one row per door, with the building details, door reference, location, rating, type, the result of each of the 13 checks and the outcome, so you can sort failures in Excel, Numbers or Google Sheets. Doors you left completely blank are skipped. The file is built in your browser; nothing is uploaded.

What to check on a fire door

  • Label or certification mark: often on the top edge of the door or the frame.
  • Door leaf and frame: no holes, damage or alterations such as cat flaps or extra locks.
  • Gaps: even around the door, typically about 3 mm at the top and sides, and an acceptable gap at the bottom.
  • Intumescent strips and smoke seals: present, continuous and not painted over.
  • Hinges: at least three on most doors, firmly fixed, with no missing screws.
  • Self-closer: closes the door fully onto the latch from any angle, without slamming.
  • Glazing: unbroken and fixed with fire-rated beads and seals.
  • Signage and use: “Fire door keep shut” sign where needed, and never wedged open.

How often should fire doors be inspected?

Under the Fire Safety (England) Regulations 2022, in residential buildings over 11 metres tall, the responsible person must check communal fire doors at least every three months and use best endeavours to check flat entrance doors at least once a year. In other premises, fire doors are part of the fire safety measures the Fire Safety Order requires you to maintain; frequent visual checks are good practice, with busy doors checked more often.

Writing certificates every week? Pro is £39/month ex VAT

  • Every certificate saved: fire alarm, emergency lighting, PAT, EIC, EICR and Minor Works
  • Your logo, company, accreditation and signature on every PDF
  • History with search, copy and re-issue
  • Renewal reminders in the app and in your calendar
  • No “Free version” mark

Business (£79/month ex VAT) adds up to 5 users, a client and site register and bulk reminders. Plans are for businesses (sole traders, partnerships and companies). The forms and calculators stay free.

See plans

Frequently asked questions

How much does a fire door inspection cost per door?

Published guide prices range from about £10 to £30 per door for a basic visual check to £35 to £80 or more for a detailed survey with photos (Fire Risk Assessment Network, read 18 November 2026), with minimum visit fees of £200 to £800 on small sites. One firm quotes surveys from £250 plus VAT and a 2026 trade guide gives £50 to £150 per door. See the table above for sources.

Who can carry out a fire door inspection?

For the routine checks in the Fire Safety (England) Regulations 2022, gov.uk says the responsible person should be able to do them themselves and a specialist should not be needed. For a detailed survey or a door whose certification is unclear, use a competent person. gov.uk gives no qualification standard, so ask a surveyor for evidence of their training or third-party certification.

Is there a fire door inspection app?

This form works on a phone browser and can be added to your home screen. For paid apps and software, see the comparison on the fire door inspection app page.

Can I inspect fire doors myself?

Routine visual checks like these can be done by a responsible person or a trained member of staff. A detailed survey of door construction, certification and repair options is a job for a competent fire door inspector.

What happens if a door fails?

Record the failure and the remedial action needed, then arrange the repair. Some faults, such as a missing closer or damaged seals, can often be fixed; serious damage or an uncertified door may mean replacing the doorset.

Is anything I type uploaded?

Not unless you choose to save it. The form and the PDF are built by your browser on your device, and a draft is kept in your browser’s local storage so you can come back to it on the same device (“Clear form” deletes it). Only when you are signed in to a Pro or Business plan and press “Save to account” is the certificate stored on our server, so you can open it on any device.

Does using this form make my premises compliant?

No. The tool only records what you enter and lays it out as a tidy document. Whether the inspection, test or assessment is suitable and sufficient depends on the person doing it and on the premises. Competence and compliance remain with you, the user.