UK fire, electrical and gas safety duties at a glance
Which law says what, who it applies to and whether it names a fixed interval. Sources are linked; this is a summary, not legal advice.
In England and Wales the Fire Safety Order 2005 makes the responsible person assess fire risk and keep fire equipment maintained, but sets no fixed alarm or lighting test interval. The Electricity at Work Regulations 1989 set no PAT interval either. Landlord gas checks are yearly and rented-home electrical checks every five years.
- Fire alarm service certificate →BS 5839-1 inspection and servicing: checks, devices, defects.
- Emergency lighting certificate →BS 5266-1 duration test with luminaire schedule.
- PAT testing certificate →Appliance register, results, retest dates and signature.
- PAT record sheet →Asset register as PDF or CSV for Excel, with retest dates.
- Fire risk assessment →Five-step template with risk rating and action plan.
- Fire door inspection →Door-by-door checklist with remedial actions.
- Fire door inspection app →Phone form plus a dated comparison of paid apps.
- Fire safety log book →Alarm tests, lighting, extinguishers, drills and servicing.
- Fire alarm log book →Weekly call point tests, false alarms and faults.
- Blank PAT template →Fillable PDF certificate and register to print.
- Legionella risk assessment →Water system, risk factors, temperatures and controls.
- HMO fire risk assessment →Common parts, escape route, fire doors and alarms.
- PEEP template →Personal emergency evacuation plan with named helpers.
- LOLER thorough examination →Next examination date and a Schedule 1 report.
- F-gas leak check record →CO2e, leak check interval and Article 6 log.
- COSHH assessment →Substance, exposure, controls, PPE and review date.
- RAMS template →Risk assessment and method statement for one job, as a PDF.
- CIS calculator →20%, 30% or 0% deduction, materials and VAT, net or gross.
- TM44 air-con inspection →Over 12 kW? Due date checker and unit register.
- Building regs certificate →Is the work notifiable, and which certificate to expect.
- Gas certificates →CP12, warning notice, service record and gas calculators.
- Electrical certificates →EIC, EICR, Minor Works and BS 7671 calculators.
Important: this tool records the results and findings you enter and formats them as a document. It does not inspect, test or assess anything. Competence and compliance remain with the user. Not legal advice.
Duties and intervals
| Duty | Law | Applies to | Fixed interval in law? |
|---|---|---|---|
| Fire risk assessment, kept under review | Regulatory Reform (Fire Safety) Order 2005, art. 9 (legislation.gov.uk/uksi/2005/1541) | Responsible person for non-domestic premises and the common parts of multi-occupied homes | No: review regularly and after changes. Significant findings must be recorded if you employ five or more people, hold a licence or an alterations notice is in force |
| Fire detection, warning and fire-fighting equipment | Fire Safety Order 2005, art. 13 | Responsible person | No. BS 5839-1 recommends servicing at no more than six-month intervals, but that is a standard, not the Order |
| Maintain safety equipment and emergency lighting | Fire Safety Order 2005, art. 17 | Responsible person | No. BS 5266-1 is the usual benchmark for testing emergency lighting |
| Escape routes and exits kept clear and usable | Fire Safety Order 2005, art. 14 | Responsible person | No |
| Competent persons, training and information | Fire Safety Order 2005, arts. 18, 19 and 21 | Responsible person and employers | No |
| Electrical systems maintained to prevent danger | Electricity at Work Regulations 1989, reg. 4 (legislation.gov.uk/uksi/1989/635) | Employers, self-employed, employees | No |
| Portable appliance (PAT) testing | Electricity at Work Regulations 1989, reg. 4(2); HSE guidance HSG107 | Employers and self-employed | No: HSE says frequency depends on the equipment and its use; there is no legal requirement for annual PAT |
| Landlord electrical inspection and test | Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 (legislation.gov.uk/uksi/2020/312) | Private landlords in England | Yes: at least every five years, report to tenants within 28 days |
| Landlord gas safety check | Gas Safety (Installation and Use) Regulations 1998, reg. 36 (legislation.gov.uk/uksi/1998/2451) | Landlords with gas appliances | Yes: every 12 months, copy to tenants within 28 days of the check and to new tenants before they move in |
| Smoke and carbon monoxide alarms | Smoke and Carbon Monoxide Alarm (England) Regulations 2015 (legislation.gov.uk/uksi/2015/1693) | Private landlords in England | Test on the first day of each tenancy; no repeating interval |
| Legionella risk control | Health and Safety at Work etc. Act 1974; HSE ACOP L8 and HSG274 | Employers and those in control of premises | No: review regularly and when circumstances change |
Scotland and Northern Ireland
Fire safety law differs: the Fire (Scotland) Act 2005 and the Fire and Rescue Services (Northern Ireland) Order 2006 apply there. The Electricity at Work Regulations 1989 apply across Great Britain; Northern Ireland has its own equivalent. Check the legislation for your premises.
Standards are not the law
British Standards such as BS 5839-1 (fire alarms), BS 5266-1 (emergency lighting) and BS 7671 (electrical installations) are the benchmarks competent people follow and that enforcing authorities look to. Where the table says there is no fixed interval in law, the interval comes from your risk assessment and the relevant standard.
Writing certificates every week? Pro is £39/month ex VAT
- Every certificate saved: fire alarm, emergency lighting, PAT, EIC, EICR and Minor Works
- Your logo, company, accreditation and signature on every PDF
- History with search, copy and re-issue
- Renewal reminders in the app and in your calendar
- No “Free version” mark
Business (£79/month ex VAT) adds up to 5 users, a client and site register and bulk reminders. Plans are for businesses (sole traders, partnerships and companies). The forms and calculators stay free.
Frequently asked questions
How often must a fire alarm be serviced by law?
The Fire Safety Order requires equipment to be maintained but sets no number of months. BS 5839-1 recommends servicing at intervals of no more than six months, and your fire risk assessment decides what applies.
Is PAT testing a legal requirement?
Not as such. The Electricity at Work Regulations 1989 require equipment to be maintained in a safe condition; HSE says there is no legal requirement for annual PAT and that frequency is risk-based.
Is this legal advice?
No. It is a plain-English summary with links to the legislation. Read the source and take advice for your own situation.